Specially designed to be buried in the concrete slab, the 6 Watt cable or mat ensures constant comfort and, when integrated into a construction from the start of the work, can generate significant savings.
Standard voltages : 240 V
Powers:
46 sq. ft. coverage | 6 inch spacing 11 W/ft 2 |
Linear foot length | 46 foot |
Output power Watt | 506 |
Power Output Amp | 2.1 Amp |
Connection to thermostat: Single connection point (no return to thermostat)
Non-heating cable : 3 m (10 ft) 2 conductors and bsp earth;
Maximum exposure temperature: (continuous and storage) 90°C (194°F)
Maximum installation temperature: 10°C (50°F)
Maximum heater current : 11 A
Maximum circuit load: 16 A
Maximum circuit protection: 20 A circuit breaker
Approvals: ULC certified in North America CSA Canada: supplemental or primary heating. Approved for showers, dry and wet environments.